A study of the installed capacity and electricity quality of a fuel cell-independent microgrid that uses locally produced energy for local consumption

https://kitami-it.repo.nii.ac.jp/records/8254
https://kitami-it.repo.nii.ac.jp/records/8254
63e525a3-1497-4c68-b377-7ea10882c2c1
名前 / ファイル ライセンス アクション
No.33_paper_modified.pdf No.33_paper_modified.pdf (973.4 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2016-07-05
タイトル
タイトル A study of the installed capacity and electricity quality of a fuel cell-independent microgrid that uses locally produced energy for local consumption
言語 en
言語
言語 eng
キーワード
主題Scheme Other
主題 SOFC
キーワード
主題Scheme Other
主題 tidal power generation
キーワード
主題Scheme Other
主題 microgrid
キーワード
主題Scheme Other
主題 Saroma Lake
キーワード
主題Scheme Other
主題 numerical simulation
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 Obara, Shin'ya

× Obara, Shin'ya

en Obara, Shin'ya

Search repository
Kawae, Osamu

× Kawae, Osamu

en Kawae, Osamu

Search repository
Kawai, Masahito

× Kawai, Masahito

en Kawai, Masahito

Search repository
Morizane, Yuta

× Morizane, Yuta

en Morizane, Yuta

Search repository
抄録
内容記述タイプ Abstract
内容記述 Reducing the rates of nuclear power generation for all electric power sources has been seriously discussed in Japan since
the accident at the Fukushima No. 1 nuclear power plant in March 2011. Thus, the distributed power supply is expected to
expand. The local production of safe and clean energy for local consumption is greatly needed in Japan. In this paper, the
Saroma Lake green microgrid (SLMG), a fuel cell microgrid using tidal power generation and photovoltaics, has been
planned. Energy balance equations were used to investigate this system’s method of operation. Further simulated analysis
of the facility, its operation cost, and the electric power quality of the network were conducted using MATLAB/Simulink,
and the relationships among the capacity of a facility, the cost, and supply rate of green energy and the electric power quality
(interphase voltage, frequency, and higher harmonic wave) of the power network were clarified. The total projected cost
of the equipment and operation for introducing the proposed SLMG is \1,500,000,000/10 years. Increasing the supply rate
of green energy and reducing the facility cost will require the introduction of biofuels and the reduction of the facility costs
of solid oxide fuel cells in the SLMG.
書誌情報 en : International Journal of Energy Research

巻 37, 号 14, p. 1764-1783, 発行日 2012
DOI
識別子タイプ DOI
関連識別子 http://doi.org/10.1002/er.2990
権利
権利情報 c2012 Wiley
権利
権利情報 This is the peer reviewed version of the following article: Int J Energ Res (2012) 37: 1764-1783, which has been published in final form at http://doi.org/10.1002/er.2990. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.
出版者
出版者 Wiley
著者版フラグ
言語 en
値 author
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 06:22:55.318369
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3