{"created":"2021-03-01T06:00:42.854880+00:00","id":8254,"links":{},"metadata":{"_buckets":{"deposit":"9416b718-7178-406c-9b06-280142e88d1e"},"_deposit":{"id":"8254","owners":[],"pid":{"revision_id":0,"type":"depid","value":"8254"},"status":"published"},"_oai":{"id":"oai:kitami-it.repo.nii.ac.jp:00008254","sets":["1:87"]},"author_link":["44843","43231","43232","43233","43234"],"item_1646810750418":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_3_biblio_info_186":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"14","bibliographicPageEnd":"1783","bibliographicPageStart":"1764","bibliographicVolumeNumber":"37","bibliographic_titles":[{"bibliographic_title":"International Journal of Energy Research","bibliographic_titleLang":"en"}]}]},"item_3_description_184":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Reducing the rates of nuclear power generation for all electric power sources has been seriously discussed in Japan since\nthe accident at the Fukushima No. 1 nuclear power plant in March 2011. Thus, the distributed power supply is expected to\nexpand. The local production of safe and clean energy for local consumption is greatly needed in Japan. In this paper, the\nSaroma Lake green microgrid (SLMG), a fuel cell microgrid using tidal power generation and photovoltaics, has been\nplanned. Energy balance equations were used to investigate this system’s method of operation. Further simulated analysis\nof the facility, its operation cost, and the electric power quality of the network were conducted using MATLAB/Simulink,\nand the relationships among the capacity of a facility, the cost, and supply rate of green energy and the electric power quality\n(interphase voltage, frequency, and higher harmonic wave) of the power network were clarified. The total projected cost\nof the equipment and operation for introducing the proposed SLMG is \\1,500,000,000/10 years. Increasing the supply rate\nof green energy and reducing the facility cost will require the introduction of biofuels and the reduction of the facility costs\nof solid oxide fuel cells in the SLMG.","subitem_description_type":"Abstract"}]},"item_3_full_name_183":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44843","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"10342437","nameIdentifierScheme":"KAKEN","nameIdentifierURI":"https://nrid.nii.ac.jp/ja/nrid/1000010342437 "}],"names":[{"name":"小原, 伸哉","nameLang":"ja"}]}]},"item_3_publisher_212":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Wiley"}]},"item_3_relation_191":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1002/er.2990","subitem_relation_type_select":"DOI"}}]},"item_3_rights_192":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"c2012 Wiley"},{"subitem_rights":"This is the peer reviewed version of the following article: Int J Energ Res (2012) 37: 1764-1783, which has been published in final form at http://doi.org/10.1002/er.2990. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving."}]},"item_3_select_195":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Obara, Shin'ya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"43231","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kawae, Osamu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"43232","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kawai, Masahito","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"43233","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Morizane, Yuta","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"43234","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-22"}],"displaytype":"detail","filename":"No.33_paper_modified.pdf","filesize":[{"value":"973.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"No.33_paper_modified.pdf","url":"https://kitami-it.repo.nii.ac.jp/record/8254/files/No.33_paper_modified.pdf"},"version_id":"907196c3-243a-47d2-9745-7ec0aa537d6d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"SOFC","subitem_subject_scheme":"Other"},{"subitem_subject":"tidal power generation","subitem_subject_scheme":"Other"},{"subitem_subject":"microgrid","subitem_subject_scheme":"Other"},{"subitem_subject":"Saroma Lake","subitem_subject_scheme":"Other"},{"subitem_subject":"numerical simulation","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A study of the installed capacity and electricity quality of a fuel cell-independent microgrid that uses locally produced energy for local consumption","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A study of the installed capacity and electricity quality of a fuel cell-independent microgrid that uses locally produced energy for local consumption","subitem_title_language":"en"}]},"item_type_id":"3","owner":"1","path":["87"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2016-07-05"},"publish_date":"2016-07-05","publish_status":"0","recid":"8254","relation_version_is_last":true,"title":["A study of the installed capacity and electricity quality of a fuel cell-independent microgrid that uses locally produced energy for local consumption"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2024-06-03T02:12:07.412398+00:00"}