Power Generation Efficiency of Photovoltaics and a SOFC-PEFC Combined Micro-grid with Time Shift Utilization of the SOFC Exhaust Heat
https://kitami-it.repo.nii.ac.jp/records/8233
https://kitami-it.repo.nii.ac.jp/records/823353e0d831-f97e-40b8-a285-19c6953b32e1
名前 / ファイル | ライセンス | アクション |
---|---|---|
2010_Power Generation Efficiency of Photovoltaics and a SOFC-PEFC Combined Micro-grid with Time Shift Utilization of the SOFC Exhaust Heat.pdf (947.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-07-04 | |||||
タイトル | ||||||
タイトル | Power Generation Efficiency of Photovoltaics and a SOFC-PEFC Combined Micro-grid with Time Shift Utilization of the SOFC Exhaust Heat | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Fuel Cell | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Micro-Gird | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Combined System | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | SOFC | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | PEFC | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
著者 |
Abeer, Galal El-Sayed
× Abeer, Galal El-Sayed× OBARA, Shin'ya |
|||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 44843 | |||||
識別子Scheme | KAKEN | |||||
識別子URI | https://nrid.nii.ac.jp/ja/nrid/1000010342437 | |||||
識別子 | 10342437 | |||||
姓名 | 小原, 伸哉 | |||||
言語 | ja | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this study, the combined system of a solid-oxide fuel cell (SOFC) and a proton-exchange membrane fuel cell (PEFC) is developed. The proposed system consists of a SOFC-PEFC combined system and a photovoltaic system (PV) as the energy supply to a micro-grid. The exhaust heat of the SOFC is used for the steam reforming of the bio-ethanol gas with time shift utilization of the exhaust heat of the SOFC in optional time. The SOFC-PEFC combined system with the PV was introduced in a micro-grid of 30 residences in Sapporo, Japan. The operation plan of the system has three cases: without solar power, with 50% and with 100% of solar output power. Moreover, three types of system operation of using the SOFC independent operation, PEFC independent operation and SOFC-PEFC combined system are used to supply the demand side. A comparative study between the types of system operation is presented. The power generation efficiency is investigated for different load patterns: average load pattern, compressed load pattern and extended load pattern. This paper reported that the power generation efficiencies of the proposedsystem in consideration of these load patterns are 27% to 48%. | |||||
書誌情報 |
Journal of Power and Energy Systems 巻 4, 号 2, p. 274-289, 発行日 2010 |
|||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://doi.org/10.1299/jpes.4.274 | |||||
権利 | ||||||
権利情報 | c 2010 by The Japan Society of Mechanical Engineers | |||||
出版者 | ||||||
出版者 | The Japan Society of Mechanical Engineers | |||||
著者版フラグ | ||||||
値 | publisher | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |