{"_buckets": {"deposit": "d634d6ac-7538-4917-a2c8-e2cb443b213a"}, "_deposit": {"id": "7899", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "7899"}, "status": "published"}, "_oai": {"id": "oai:kitami-it.repo.nii.ac.jp:00007899", "sets": ["86"]}, "author_link": ["40779", "40780", "40776", "44816", "40778"], "item_1646810750418": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_3_alternative_title_198": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Optimization of System Performance on a Biogas Cogeneration in a Sewage Treatment Center"}]}, "item_3_biblio_info_186": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "789", "bibliographicPageEnd": "1062", "bibliographicPageStart": "1058", "bibliographicVolumeNumber": "78", "bibliographic_titles": [{"bibliographic_title": "日本機械学会論文集 B編", "bibliographic_titleLang": "ja"}]}]}, "item_3_description_184": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "An efficient configuration method of a biogas-fuelled cogeneration system (CGS) in a sewage treatment center was investigated. The efficient configuration was clarified by classifying a relationship between exhaust heat recovery efficiency (ηehr) of a micro gas turbine CGS, and the ratio of average heat demand to biogas production of the facility (Qh.d/Qb.p). It was found that on the point of view of biogas energy recovery, reduction of unutilized biogas and electrical power demand efficiencies, the most efficient CGS was obtained under Qh.d/Qb.p = ηehr condition. If a CGS with lower ηehr such as a fuel cell is used under Qh.d/Qb.p \u003c ηehr condition, or a CGS with higher ηehr such as a steam turbine is used under Qh.d/Qb.p \u003e ηehr condition, more efficient system can be obtained. On the other hand, suggestion for more efficient system when ηehr cannot be conformed to the Qh.d/Qb.p value was also presented.", "subitem_description_type": "Abstract"}]}, "item_3_full_name_183": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "40779", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "YAMADA, Takanobu", "nameLang": "en"}]}, {"nameIdentifiers": [{"nameIdentifier": "40780", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "NAKANISHI, Kimio", "nameLang": "en"}]}]}, "item_3_publisher_212": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "一般社団法人日本機械学会"}]}, "item_3_relation_191": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://doi.org/10.1299/kikaib.78.1058", "subitem_relation_type_select": "DOI"}}]}, "item_3_rights_192": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c 2012 一般社団法人日本機械学会"}]}, "item_3_select_195": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_3_subject_196": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "533", "subitem_subject_scheme": "NDC"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Firdaus, BASRAWI", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "40776", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田, 貴延", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "44816", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90174721", "nameIdentifierScheme": "KAKEN", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000090174721 "}]}, {"creatorNames": [{"creatorName": "中西, 喜美雄", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "40778", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-11-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "No10.pdf", "filesize": [{"value": "802.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 802200.0, "url": {"label": "No10.pdf", "url": "https://kitami-it.repo.nii.ac.jp/record/7899/files/No10.pdf"}, "version_id": "61b340ff-ab42-44e1-a9bb-e59eabf3aca6"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Biomass", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Biogas", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Cogeneration System", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Micro Gas Turbine", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Sewage Treatment Center", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "下水処理施設で稼働するバイオガスコジェネレーションシステムの性能最適化", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "下水処理施設で稼働するバイオガスコジェネレーションシステムの性能最適化", "subitem_title_language": "ja"}, {"subitem_title": "Optimization of System Performance on a Biogas Cogeneration in a Sewage Treatment Center", "subitem_title_language": "en"}]}, "item_type_id": "3", "owner": "1", "path": ["86"], "permalink_uri": "https://kitami-it.repo.nii.ac.jp/records/7899", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2015-08-18"}, "publish_date": "2015-08-18", "publish_status": "0", "recid": "7899", "relation": {}, "relation_version_is_last": true, "title": ["下水処理施設で稼働するバイオガスコジェネレーションシステムの性能最適化"], "weko_shared_id": -1}
下水処理施設で稼働するバイオガスコジェネレーションシステムの性能最適化
https://kitami-it.repo.nii.ac.jp/records/7899
https://kitami-it.repo.nii.ac.jp/records/7899b7b8d5f9-b525-4f9e-9e6f-b109c81ec511
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-08-18 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 下水処理施設で稼働するバイオガスコジェネレーションシステムの性能最適化 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Optimization of System Performance on a Biogas Cogeneration in a Sewage Treatment Center | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Biomass | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Biogas | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Cogeneration System | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Micro Gas Turbine | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Sewage Treatment Center | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
その他のタイトル | ||||||
その他のタイトル | Optimization of System Performance on a Biogas Cogeneration in a Sewage Treatment Center | |||||
著者 |
Firdaus, BASRAWI
× Firdaus, BASRAWI× 山田, 貴延× 中西, 喜美雄 |
|||||
著者別名 | ||||||
姓名 | YAMADA, Takanobu | |||||
言語 | en | |||||
著者別名 | ||||||
姓名 | NAKANISHI, Kimio | |||||
言語 | en | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | An efficient configuration method of a biogas-fuelled cogeneration system (CGS) in a sewage treatment center was investigated. The efficient configuration was clarified by classifying a relationship between exhaust heat recovery efficiency (ηehr) of a micro gas turbine CGS, and the ratio of average heat demand to biogas production of the facility (Qh.d/Qb.p). It was found that on the point of view of biogas energy recovery, reduction of unutilized biogas and electrical power demand efficiencies, the most efficient CGS was obtained under Qh.d/Qb.p = ηehr condition. If a CGS with lower ηehr such as a fuel cell is used under Qh.d/Qb.p < ηehr condition, or a CGS with higher ηehr such as a steam turbine is used under Qh.d/Qb.p > ηehr condition, more efficient system can be obtained. On the other hand, suggestion for more efficient system when ηehr cannot be conformed to the Qh.d/Qb.p value was also presented. | |||||
書誌情報 |
ja : 日本機械学会論文集 B編 巻 78, 号 789, p. 1058-1062, 発行日 2012-05 |
|||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://doi.org/10.1299/kikaib.78.1058 | |||||
権利 | ||||||
権利情報 | c 2012 一般社団法人日本機械学会 | |||||
出版者 | ||||||
出版者 | 一般社団法人日本機械学会 | |||||
著者版フラグ | ||||||
値 | publisher | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |