Superficial vascular imaging system using near infrared radiation and tomo-synthesis algorithm, Tuned-Aperture Computed Tomography
https://kitami-it.repo.nii.ac.jp/records/7542
https://kitami-it.repo.nii.ac.jp/records/75420b1ffa21-2b08-4af9-8395-b71517b96a62
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-03-18 | |||||
タイトル | ||||||
タイトル | Superficial vascular imaging system using near infrared radiation and tomo-synthesis algorithm, Tuned-Aperture Computed Tomography | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | near infrared imaging | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | tomo-synthesis | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | vascular imaging | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | vein pattern | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_5794 | |||||
タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
その他のタイトル | ||||||
その他のタイトル | CARDIAC AND VASCULAR IMAGING | |||||
言語 | en | |||||
著者 |
Hayakawa, Y.
× Hayakawa, Y.× Miyoseta, Y.× Yamashita, H.× Sagawa, M. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | To develop the superficial vascular imaging system using near infrared radiation and tomo-synthesis algorithm, Tuned-Aperture Computed Tomography. Near infrared sensitive CCD camera was surrounded by approximately sixty light emitting diodes, which have alternating wavelengths of 700 nm and 810 nm. NIR-sensitive camera detected the reflected NIR from superficial subcutaneous tissues. By rotating the camera and LEDs, multiple near infrared projections of superficial vascular images were obtained at each wavelength, and tomo-synthesis algorithm in accordance with the optical aperture theory was applied to a group of images. The depth discrimination was obtained by the TACT program. Due to the difference and similarity in the absorption coefficients at 700 nm, 810 nm and 940 nm wavelength, the venous oxygenation index (VOI) was estimated by signal intensities at each wavelength. The VOI was seemed to reflect the oxygen saturation level. Results: The superficial vascular imaging system using near infrared radiation and tomo-synthesis algorithm created thin tomograms of superficial vascular subcutaneous tissues. Changes in VOL after the load test were more significantly observed on tomograms than on projection images. The superficial vascular imaging system using near infrared radiation and tomo-synthesis algorithm enable to carry out the non-invasive tomograms and provide estimates of in oxygen saturation. Also we confirmed that the system is the beneficial tool for finding subcutaneous foreign bodies. |
|||||
言語 | en | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Proceedings of the 22nd International Congress and Exhibition, Barcelona, Spain, June 25-28, 2008 | |||||
言語 | en | |||||
書誌情報 |
International Journal of Computer Assisted Radiology and Surgery 巻 3, 号 1 Suppl., p. S26-S27, 発行日 2008-06 |
|||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://doi.org/10.1007/s11548-008-0168-y | |||||
著者版フラグ | ||||||
言語 | en | |||||
値 | author | |||||
出版者 | ||||||
出版者 | Springer |