  1. 学術雑誌論文
  2. 洋雑誌

Comparison of two- and three-dimensional filtering methods to improve image quality in multiplanar reconstruction of cone-beam computed tomography

https://kitami-it.repo.nii.ac.jp/records/7527
https://kitami-it.repo.nii.ac.jp/records/7527
79c9c29a-44f2-4ef6-960b-72b0947a905c
名前 / ファイル ライセンス アクション
Sagawa_etal_finalform_Oral_Radiol_2009.pdf Sagawa_etal_finalform_Oral_Radiol_2009.pdf (206.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-06-12
タイトル
タイトル Comparison of two- and three-dimensional filtering methods to improve image quality in multiplanar reconstruction of cone-beam computed tomography
言語 en
言語
言語 eng
キーワード
主題Scheme Other
主題 Computed tomography
キーワード
主題Scheme Other
主題 cone beam - Digital filtration - Smoothing filter
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 Sagawa, Morihisa

× Sagawa, Morihisa

en Sagawa, Morihisa

Search repository
Miyoseta, Yasutaka

× Miyoseta, Yasutaka

en Miyoseta, Yasutaka

Search repository
Hayakawa, Yoshihiko

× Hayakawa, Yoshihiko

en Hayakawa, Yoshihiko

Search repository
Honda, Akira

× Honda, Akira

en Honda, Akira

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objectives: Two- and three-dimensional (2D and 3D, respectively) filtering methods were examined to improve the accuracy of bone morphology depicted in dental cone-beam computed tomography (CBCT) images. An attempt to improve multiplanar reconstruction (MPR) image quality was carried out by reducing the image noise.
Methods: CBCT examinations were performed with the following principal exposure parameters: I-mode, FOV 10 cm in diameter, 120 kV, 15 mA, 0.2 mm slice thickness, and exposure time of 10 s. 2D and 3D filtering procedures for averaging, median smoothing, and Gaussian smoothing were applied for improvement of MPR images. For comparison, 2D and 3D Laplacian sharpening for images preprocessed by Gaussian sharpening was also tested.
Results: MPR images at the midsagittal plane on the maxilla are presented. Three smoothing filters yielded improvements in slightly different ways. The Gaussian filter clearly showed moderate changes. Small but obvious differences were observed between 2D and 3D filtering. When we focused on the depiction of bone contours, the effects of these noise reduction filters seemed to be minimal in morphological bone depiction. The Laplacian filter was useful for sharpening and emphasized noise in the resulting images, in contrast to those processed by smoothing filters.
Conclusions: Various smoothing filtering methods reduced the noise on MPR images of CBCT and also functioned differently between 2D and 3D filtering matrices.
書誌情報 Oral radiology

巻 25, 号 2, p. 154-158, 発行日 2009
DOI
識別子タイプ DOI
関連識別子 http://doi.org/10.1007/s11282-009-0026-9
出版者
出版者 Springer
言語 en
著者版フラグ
言語 en
値 author
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 06:26:53.013925
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3