{"_buckets": {"deposit": "712ff2d5-6ef8-41ed-b847-78dddc0c8d8c"}, "_deposit": {"id": "7465", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "7465"}, "status": "published"}, "_oai": {"id": "oai:kitami-it.repo.nii.ac.jp:00007465", "sets": ["1:86"]}, "author_link": ["38303", "38304", "44843", "38302"], "item_1646810750418": {"attribute_name": "\u51fa\u7248\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_3_alternative_title_198": {"attribute_name": "\u305d\u306e\u4ed6\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "Output Responce Characteristics of a Small-scale Fuel Cell for House"}]}, "item_3_biblio_info_186": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "713", "bibliographicPageEnd": "169", "bibliographicPageStart": "162", "bibliographicVolumeNumber": "72", "bibliographic_titles": [{"bibliographic_title": "\u65e5\u672c\u6a5f\u68b0\u5b66\u6703\u8ad6\u6587\u96c6 B\u7de8"}]}]}, "item_3_description_184": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "The transfer function for heat output of each component which constitutes a solid-polymer-membrane-type fuel cell was determined from transient response characteristics. All the transfer functions were expressed with time lag of first order, and the transient response characteristics of whole-system heat output was investigated using these transfer functions. As a result, the response characteristic for follow-up of electric power load is good. However, the exhaust heat output of a fuel cell and a reformer has dramatically slow response speed. In order to maintain the high efficiency of the system, the device about the heat recovery by thermal storage and utilization by a time shift is required. Since the speed of response of the heat of a system is slow, exhaust heat recovery reaches at midnight. From analysis results, although the response characteristics are good about follow of electric power load, the exhaust heat output of a fuel cell and a reformer is considered to be what has very slow speed of response.", "subitem_description_type": "Abstract"}]}, "item_3_description_194": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_3_full_name_183": {"attribute_name": "\u8457\u8005\u5225\u540d", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "38303", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "OBARA, Shinya", "nameLang": "en"}]}, {"nameIdentifiers": [{"nameIdentifier": "38304", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "KUDO, Kazuhiko", "nameLang": "en"}]}]}, "item_3_publisher_212": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a"}]}, "item_3_select_195": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_access_right": {"attribute_name": "\u30a2\u30af\u30bb\u30b9\u6a29", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u5c0f\u539f, \u4f38\u54c9", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "44843", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10342437", "nameIdentifierScheme": "KAKEN", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000010342437 "}]}, {"creatorNames": [{"creatorName": "\u5de5\u85e4, \u4e00\u5f66", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "38302", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-11-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "03_02obara.pdf", "filesize": [{"value": "743.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 743200.0, "url": {"label": "03_02obara.pdf", "url": "https://kitami-it.repo.nii.ac.jp/record/7465/files/03_02obara.pdf"}, "version_id": "7a34783f-871a-4601-9b67-f09c313e86db"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "Fuel Cell", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Transiet Responce", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Energy Saving", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Power Plant", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u5bb6\u5ead\u7528\u71c3\u6599\u96fb\u6c60\u306e\u51fa\u529b\u5fdc\u7b54\u7279\u6027", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u5bb6\u5ead\u7528\u71c3\u6599\u96fb\u6c60\u306e\u51fa\u529b\u5fdc\u7b54\u7279\u6027", "subitem_title_language": "ja"}, {"subitem_title": "Output Responce Characteristics of a Small-scale Fuel Cell for House", "subitem_title_language": "en"}]}, "item_type_id": "3", "owner": "1", "path": ["1/86"], "permalink_uri": "https://kitami-it.repo.nii.ac.jp/records/7465", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-04-08"}, "publish_date": "2010-04-08", "publish_status": "0", "recid": "7465", "relation": {}, "relation_version_is_last": true, "title": ["\u5bb6\u5ead\u7528\u71c3\u6599\u96fb\u6c60\u306e\u51fa\u529b\u5fdc\u7b54\u7279\u6027"], "weko_shared_id": -1}
  1. 学術雑誌掲載済論文
  2. 和雑誌

家庭用燃料電池の出力応答特性

https://kitami-it.repo.nii.ac.jp/records/7465
f4d5e24c-71ef-4637-b0bb-81581d056cf3
名前 / ファイル ライセンス アクション
03_02obara.pdf 03_02obara.pdf (743.2 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-04-08
タイトル
言語 ja
タイトル 家庭用燃料電池の出力応答特性
タイトル
言語 en
タイトル Output Responce Characteristics of a Small-scale Fuel Cell for House
言語
言語 jpn
キーワード
主題Scheme Other
主題 Fuel Cell
キーワード
主題Scheme Other
主題 Transiet Responce
キーワード
主題Scheme Other
主題 Energy Saving
キーワード
主題Scheme Other
主題 Power Plant
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
その他のタイトル
その他のタイトル Output Responce Characteristics of a Small-scale Fuel Cell for House
著者 小原, 伸哉

× 小原, 伸哉

WEKO 44843
KAKEN 10342437

ja 小原, 伸哉

Search repository
工藤, 一彦

× 工藤, 一彦

WEKO 38302

ja 工藤, 一彦

Search repository
著者別名
姓名
姓名 OBARA, Shinya
言語 en
著者別名
姓名
姓名 KUDO, Kazuhiko
言語 en
抄録
内容記述タイプ Abstract
内容記述 The transfer function for heat output of each component which constitutes a solid-polymer-membrane-type fuel cell was determined from transient response characteristics. All the transfer functions were expressed with time lag of first order, and the transient response characteristics of whole-system heat output was investigated using these transfer functions. As a result, the response characteristic for follow-up of electric power load is good. However, the exhaust heat output of a fuel cell and a reformer has dramatically slow response speed. In order to maintain the high efficiency of the system, the device about the heat recovery by thermal storage and utilization by a time shift is required. Since the speed of response of the heat of a system is slow, exhaust heat recovery reaches at midnight. From analysis results, although the response characteristics are good about follow of electric power load, the exhaust heat output of a fuel cell and a reformer is considered to be what has very slow speed of response.
書誌情報 日本機械学會論文集 B編

巻 72, 号 713, p. 162-169, 発行日 2006-01
フォーマット
内容記述タイプ Other
内容記述 application/pdf
出版者
出版者 日本機械学会
著者版フラグ
値 publisher
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 06:37:03.408551