WEKO3
アイテム
{"_buckets": {"deposit": "258790eb-d609-4bf8-92e8-676edf885c01"}, "_deposit": {"id": "6786", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "6786"}, "status": "published"}, "_oai": {"id": "oai:kitami-it.repo.nii.ac.jp:00006786", "sets": ["53"]}, "item_2_alternative_title_18": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Study on Climate Control System for Residental and Agricultural Building using underground Air Tunnel in Cold Regions -Field Measurement on ThemaI Effect of the Ground using underground Air Tunnel for outdoor Air lntake -"}]}, "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "13", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "北見工業大学研究報告"}]}]}, "item_2_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This passive winter air preheating technique utilizes the underground soil temperature, which stays fairly constant (approximately 10℃in wintertime)at a depth of 5 m. This study describes the winter air preheating performance of an underground air tunnel connected to a sma11-scale test house in Kitami. The air tunnel was installed at a depth of 4.5m.The results of these field measurements showed that underground air tunnels can reduce severe cold weather conditions in cold regions.", "subitem_description_type": "Abstract"}]}, "item_2_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "34281", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "MIKI, Yasutomi"}]}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "北見工業大学"}]}, "item_2_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "三木, 康臣"}], "nameIdentifiers": [{"nameIdentifier": "34280", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-11-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "33-1-1.pdf", "filesize": [{"value": "5.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 5000000.0, "url": {"label": "33-1-1.pdf", "url": "https://kitami-it.repo.nii.ac.jp/record/6786/files/33-1-1.pdf"}, "version_id": "5e2e7598-20a0-4325-a14b-b59b46f25cd8"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "寒冷地における地下エアトンネルによる外気負荷軽減に関する研究-冬季の外気取り入れ効果に関するフィールド実験", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "寒冷地における地下エアトンネルによる外気負荷軽減に関する研究-冬季の外気取り入れ効果に関するフィールド実験"}]}, "item_type_id": "2", "owner": "1", "path": ["53"], "permalink_uri": "https://kitami-it.repo.nii.ac.jp/records/6786", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-04-09"}, "publish_date": "2007-04-09", "publish_status": "0", "recid": "6786", "relation": {}, "relation_version_is_last": true, "title": ["寒冷地における地下エアトンネルによる外気負荷軽減に関する研究-冬季の外気取り入れ効果に関するフィールド実験"], "weko_shared_id": 3}
寒冷地における地下エアトンネルによる外気負荷軽減に関する研究-冬季の外気取り入れ効果に関するフィールド実験
https://kitami-it.repo.nii.ac.jp/records/6786
https://kitami-it.repo.nii.ac.jp/records/6786a2ddcc59-5332-4105-9471-ab50dd61f65b
名前 / ファイル | ライセンス | アクション |
---|---|---|
33-1-1.pdf (5.0 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-04-09 | |||||
タイトル | ||||||
タイトル | 寒冷地における地下エアトンネルによる外気負荷軽減に関する研究-冬季の外気取り入れ効果に関するフィールド実験 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他のタイトル | ||||||
その他のタイトル | Study on Climate Control System for Residental and Agricultural Building using underground Air Tunnel in Cold Regions -Field Measurement on ThemaI Effect of the Ground using underground Air Tunnel for outdoor Air lntake - | |||||
著者 |
三木, 康臣
× 三木, 康臣 |
|||||
著者別名 | ||||||
識別子 | 34281 | |||||
識別子Scheme | WEKO | |||||
姓名 | MIKI, Yasutomi | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This passive winter air preheating technique utilizes the underground soil temperature, which stays fairly constant (approximately 10℃in wintertime)at a depth of 5 m. This study describes the winter air preheating performance of an underground air tunnel connected to a sma11-scale test house in Kitami. The air tunnel was installed at a depth of 4.5m.The results of these field measurements showed that underground air tunnels can reduce severe cold weather conditions in cold regions. | |||||
書誌情報 |
北見工業大学研究報告 巻 33, 号 1, p. 1-13, 発行日 2001-09 |
|||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
値 | publisher | |||||
出版者 | ||||||
出版者 | 北見工業大学 |