{"_buckets": {"deposit": "954c63f1-4131-4326-ba82-83139d425dc9"}, "_deposit": {"id": "6520", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "6520"}, "status": "published"}, "_oai": {"id": "oai:kitami-it.repo.nii.ac.jp:00006520", "sets": ["34"]}, "item_2_alternative_title_18": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Current of Negative DC Surface Discharges"}]}, "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1981-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "48", "bibliographicPageStart": "41", "bibliographicVolumeNumber": "13", "bibliographic_titles": [{"bibliographic_title": "北見工業大学研究報告"}]}]}, "item_2_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Measures of voltage and current were made at the same time using an electro-m agnetic oscillograph. Surface discharges with and without a backing electrode using the needle-to-blade of a razor gap were taken. The experiments were performed in dry air of close to O% relative humidity at 101.32 kPa pressure. Acryl resin was used in the sample plates as the electaical insulator. In the results, the current pulse of the discharge without a backing electrode was of a high frequency and the current pulse of the discharge with a backing electrode was of a scattered nature. It was confirmed by the appearance of the frequency of the current pulse that the life time of charges accumulated on the insulator in the discharge using a backing electrode was longer than when the discharge was produced without a backing electrode.", "subitem_description_type": "Abstract"}]}, "item_2_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "32909", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Noriyoshi, SUGAWARA"}]}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "北見工業大学"}]}, "item_2_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "菅原, 宣義"}], "nameIdentifiers": [{"nameIdentifier": "32908", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-11-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "13-1-5.pdf", "filesize": [{"value": "3.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 3200000.0, "url": {"label": "13-1-5.pdf", "url": "https://kitami-it.repo.nii.ac.jp/record/6520/files/13-1-5.pdf"}, "version_id": "c4a4f9a1-38f4-4157-a5cd-3859d4921f00"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "負極性直流沿面放電の電流*", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "負極性直流沿面放電の電流*"}]}, "item_type_id": "2", "owner": "1", "path": ["34"], "permalink_uri": "https://kitami-it.repo.nii.ac.jp/records/6520", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-04-09"}, "publish_date": "2007-04-09", "publish_status": "0", "recid": "6520", "relation": {}, "relation_version_is_last": true, "title": ["負極性直流沿面放電の電流*"], "weko_shared_id": 3}
負極性直流沿面放電の電流*
https://kitami-it.repo.nii.ac.jp/records/6520
https://kitami-it.repo.nii.ac.jp/records/6520b20d90c3-ac30-447c-bcf8-6e25d46424ec
名前 / ファイル | ライセンス | アクション |
---|---|---|
13-1-5.pdf (3.2 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-04-09 | |||||
タイトル | ||||||
タイトル | 負極性直流沿面放電の電流* | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他のタイトル | ||||||
その他のタイトル | Current of Negative DC Surface Discharges | |||||
著者 |
菅原, 宣義
× 菅原, 宣義 |
|||||
著者別名 | ||||||
識別子 | 32909 | |||||
識別子Scheme | WEKO | |||||
姓名 | Noriyoshi, SUGAWARA | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Measures of voltage and current were made at the same time using an electro-m agnetic oscillograph. Surface discharges with and without a backing electrode using the needle-to-blade of a razor gap were taken. The experiments were performed in dry air of close to O% relative humidity at 101.32 kPa pressure. Acryl resin was used in the sample plates as the electaical insulator. In the results, the current pulse of the discharge without a backing electrode was of a high frequency and the current pulse of the discharge with a backing electrode was of a scattered nature. It was confirmed by the appearance of the frequency of the current pulse that the life time of charges accumulated on the insulator in the discharge using a backing electrode was longer than when the discharge was produced without a backing electrode. | |||||
書誌情報 |
北見工業大学研究報告 巻 13, 号 1, p. 41-48, 発行日 1981-10 |
|||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
値 | publisher | |||||
出版者 | ||||||
出版者 | 北見工業大学 |