{"created":"2021-03-01T06:00:46.446961+00:00","id":8425,"links":{},"metadata":{"_buckets":{"deposit":"b6a5823f-dcaf-493f-8cd3-2f309031bdd3"},"_deposit":{"id":"8425","owners":[],"pid":{"revision_id":0,"type":"depid","value":"8425"},"status":"published"},"_oai":{"id":"oai:kitami-it.repo.nii.ac.jp:00008425","sets":["1:87"]},"author_link":["44356","44851","44852","44352","44353","44354","44355"],"item_1646810750418":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_3_biblio_info_186":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"9","bibliographicPageEnd":"1110","bibliographicPageStart":"1101","bibliographicVolumeNumber":"124","bibliographic_titles":[{"bibliographic_title":"IEEJ Transactions on Power and Energy"}]}]},"item_3_description_184":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper investigates the function of DASM (Doubly-fed ASynchronous Machine) with emphasis placed on its ability to the stabilization of the power system including wind generators. P (active power) and Q (reactive power) compensation from DASM can be regulated independently through secondary-excitation controlling. Simulation results by PSCAD show that DASM can restore the wind-generator system to a normal operating condition rapidly even following severe transmission-line failures. Comparison studies have also been performed between wind turbine pitch control and proposed method.","subitem_description_type":"Abstract"}]},"item_3_full_name_183":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44356","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Tamura, Junji","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"44851","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"60301975","nameIdentifierScheme":"KAKEN","nameIdentifierURI":"https://nrid.nii.ac.jp/ja/nrid/1000060301975 "}],"names":[{"name":"高橋, 理音","nameLang":"ja"}]},{"nameIdentifiers":[{"nameIdentifier":"44852","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"40171897","nameIdentifierScheme":"KAKEN","nameIdentifierURI":"https://nrid.nii.ac.jp/ja/nrid/1000040171897 "}],"names":[{"name":"田村, 淳二","nameLang":"ja"}]}]},"item_3_publisher_212":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Institute of Electrical Engineers of Japan"}]},"item_3_relation_191":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1541/ieejpes.124.1101","subitem_relation_type_select":"DOI"}}]},"item_3_rights_192":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"c 2004 by the Institute of Electrical Engineers of Japan"}]},"item_3_select_195":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Wu, Li","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takahashi, Rion","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nakagawa, Masaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Murata, Toshiaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-01-12"}],"displaytype":"detail","filename":"2004_A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine.pdf","filesize":[{"value":"221.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2004_A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine.pdf","url":"https://kitami-it.repo.nii.ac.jp/record/8425/files/2004_A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine.pdf"},"version_id":"115d6489-0f74-4e50-80d4-8999f96520dc"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"DASM (doubly-fed asynchronous machine)","subitem_subject_scheme":"Other"},{"subitem_subject":"wind generator","subitem_subject_scheme":"Other"},{"subitem_subject":"wind turbine pitch control","subitem_subject_scheme":"Other"},{"subitem_subject":"PSCAD/EMTDC","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine","subitem_title_language":"en"}]},"item_type_id":"3","owner":"1","path":["87"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2016-08-19"},"publish_date":"2016-08-19","publish_status":"0","recid":"8425","relation_version_is_last":true,"title":["A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2024-06-03T02:12:08.811726+00:00"}