{"created":"2021-03-01T06:00:45.903074+00:00","id":8416,"links":{},"metadata":{"_buckets":{"deposit":"ee830ce4-7b74-4201-85f1-ef02f69ef05b"},"_deposit":{"id":"8416","owners":[],"pid":{"revision_id":0,"type":"depid","value":"8416"},"status":"published"},"_oai":{"id":"oai:kitami-it.repo.nii.ac.jp:00008416","sets":["1:86"]},"author_link":["44288","44289","44290","44285","44286","44852"],"item_1646810750418":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_3_alternative_title_198":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"A Consideration on the Extension of the Dead Time by Superconducting Fault Current Limiter"}]},"item_3_biblio_info_186":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"148","bibliographicPageStart":"147","bibliographicVolumeNumber":"122","bibliographic_titles":[{"bibliographic_title":"電気学会論文誌B"}]}]},"item_3_description_184":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents the results of analyses of the extension of the dead time by superconducting fault current limiter (SFCL). Although SFCL is generally used for the purpose of limiting of fault currents, it can also be used to stabilize synchronous generators. Therefore, as the transient stability when the fault occurs is enhanced effectively by SFCL, the reclosing time of circuit breakers can be delayed. It means the possibility of unsuccessful reclosing of circuit breakers can be lowered.","subitem_description_type":"Abstract"}]},"item_3_full_name_183":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44288","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yagami, Masaki","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"44289","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Murata, Toshiaki","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"44290","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Tamura, Junji","nameLang":"en"}]}]},"item_3_publisher_212":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"一般社団法人 電気学会"}]},"item_3_rights_192":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"c 2002 電気学会"}]},"item_3_select_195":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"矢神, 雅規","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"村田, 年昭","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"田村, 淳二","creatorNameLang":"ja"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-01-12"}],"displaytype":"detail","filename":"2002_超電導限流器による無電圧時間の延長に関する検討 (研究開発レター).pdf","filesize":[{"value":"216.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2002_超電導限流器による無電圧時間の延長に関する検討 (研究開発レター).pdf","url":"https://kitami-it.repo.nii.ac.jp/record/8416/files/2002_超電導限流器による無電圧時間の延長に関する検討 (研究開発レター).pdf"},"version_id":"c597d1cc-c68f-4d06-911b-df1290b3211a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"超電導限流器 (SFCL)","subitem_subject_scheme":"Other"},{"subitem_subject":"同期発電機","subitem_subject_scheme":"Other"},{"subitem_subject":"EMTP","subitem_subject_scheme":"Other"},{"subitem_subject":"無電圧時間","subitem_subject_scheme":"Other"},{"subitem_subject":"再閉路失敗","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"超電導限流器による無電圧時間の延長に関する検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"超電導限流器による無電圧時間の延長に関する検討","subitem_title_language":"ja"},{"subitem_title":"A Consideration on the Extension of the Dead Time by Superconducting Fault Current Limiter","subitem_title_language":"en"}]},"item_type_id":"3","owner":"1","path":["86"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2016-08-19"},"publish_date":"2016-08-19","publish_status":"0","recid":"8416","relation_version_is_last":true,"title":["超電導限流器による無電圧時間の延長に関する検討"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-13T02:21:54.315680+00:00"}