{"created":"2021-03-01T06:00:37.162382+00:00","id":8160,"links":{},"metadata":{"_buckets":{"deposit":"40703db9-968a-4a18-9bb0-492df4cc0d3c"},"_deposit":{"id":"8160","owners":[],"pid":{"revision_id":0,"type":"depid","value":"8160"},"status":"published"},"_oai":{"id":"oai:kitami-it.repo.nii.ac.jp:00008160","sets":["1:87"]},"author_link":["42729","42730","42731"],"item_1646810750418":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_3_biblio_info_186":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2015","bibliographicPageEnd":"1058","bibliographicPageStart":"1052","bibliographicVolumeNumber":"75","bibliographic_titles":[{"bibliographic_title":"Energy Procedia"}]}]},"item_3_description_184":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper investigates the optimum size of Micro Gas Turbine Cogeneration Systems (MGT-CGSs) in a sewage treatment plant in relation to its economic performance. A sewage treatment plant in a cold region was adopted as a model, and three units of MGT-CGS with power output capacity of 30, 65 and 200 kW were simulated to utilize biogas produced in-house in the plant. The energy balance of the system was first studied, and economic performance using Net Present Value method was carried out. It was found that a configuration with optimum combination of 3 types of MGTs (MGT-Combined) stated above had the highest power generation efficiency. However, MGT-Combinedneededmore units of MGT resulting in higher capital investment. Although all configurations of MGT-CGSs studied can generate Net Present Value (NPV) in the range of US$2,640,000-3,100,00, MGT-200had the highest NPV. MGT-200 had15% higher NPV compared to the lowest one,MGT-30. MGT-200 can generate the highest NPV because it had thelowest capital investment cost, while having high power cost savings.","subitem_description_type":"Abstract"}]},"item_3_publisher_212":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier"}]},"item_3_relation_191":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1016/j.egypro.2015.07.468","subitem_relation_type_select":"DOI"}}]},"item_3_rights_192":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"c 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license(http://creativecommons.org/licenses/by-nc-nd/4.0/)."}]},"item_3_select_195":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Basrawi, Firdaus","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ibrahim, Hassan","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamada, Takanobu","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-22"}],"displaytype":"detail","filename":"2015_Optimal Unit Sizing of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems in a Sewage Treatment Plant .pdf","filesize":[{"value":"530.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2015_Optimal Unit Sizing of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems in a Sewage Treatment Plant .pdf","url":"https://kitami-it.repo.nii.ac.jp/record/8160/files/2015_Optimal Unit Sizing of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems in a Sewage Treatment Plant .pdf"},"version_id":"b810074e-9bf3-450d-992f-b6231b836638"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Micro gas turbine","subitem_subject_scheme":"Other"},{"subitem_subject":"Cogeneration System","subitem_subject_scheme":"Other"},{"subitem_subject":"Sewage treatment plant","subitem_subject_scheme":"Other"},{"subitem_subject":"Biogas","subitem_subject_scheme":"Other"},{"subitem_subject":"Economic analysis","subitem_subject_scheme":"Other"},{"subitem_subject":"Sizing effect","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Optimal Unit Sizing of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems in a Sewage Treatment Plant","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Optimal Unit Sizing of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems in a Sewage Treatment Plant","subitem_title_language":"en"}]},"item_type_id":"3","owner":"1","path":["87"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2016-04-18"},"publish_date":"2016-04-18","publish_status":"0","recid":"8160","relation_version_is_last":true,"title":["Optimal Unit Sizing of Biogas-Fuelled Micro Gas Turbine Cogeneration Systems in a Sewage Treatment Plant"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-13T02:21:44.707263+00:00"}