{"created":"2021-03-01T05:59:41.364027+00:00","id":7238,"links":{},"metadata":{"_buckets":{"deposit":"f994ed3e-2bd2-4516-b5f8-fa03d7095a16"},"_deposit":{"id":"7238","owners":[],"pid":{"revision_id":0,"type":"depid","value":"7238"},"status":"published"},"_oai":{"id":"oai:kitami-it.repo.nii.ac.jp:00007238","sets":["1:87"]},"author_link":["37110","37111","37112"],"item_1646810750418":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_3_biblio_info_186":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"150","bibliographicPageStart":"144","bibliographicVolumeNumber":"15","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Control Systems Technology"}]}]},"item_3_description_184":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents a fuzzy logic-controlled superconducting magnetic energy storage (SMES) to improve the transient stability of an electric power system. In order to see how effective the proposed fuzzy controlled SMES in improving the transient stability is, its performance is compared to that of a conventional proportional-integral (PI) controlled SMES. Furthermore, a comparative study between the fuzzy controlled SMES and fuzzy controlled braking resistor (BR) is carried out. Simulation results show that the performance of fuzzy controlled SMES is better than that of PI controlled SMES. Again, the performance of SMES is better than that of BR. Finally, it can be concluded that the proposed fuzzy controlled SMES provides a very simple and effective means of transient stability enhancement of electric power systems","subitem_description_type":"Abstract"}]},"item_3_description_194":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_3_publisher_212":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electrical and Electronics Engineers"}]},"item_3_relation_191":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1109/TCST.2006.883342","subitem_relation_type_select":"DOI"}}]},"item_3_select_195":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ali, Mohd.Hasan","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Murata, Toshiaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tamura, Junji","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-22"}],"displaytype":"detail","filename":"ieee15_144-150.pdf","filesize":[{"value":"6.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ieee15_144-150.pdf","url":"https://kitami-it.repo.nii.ac.jp/record/7238/files/ieee15_144-150.pdf"},"version_id":"97334965-2b14-4e39-953f-79bca10ff075"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"balanced and unbalanced faults","subitem_subject_scheme":"Other"},{"subitem_subject":"braking resistor (BR)","subitem_subject_scheme":"Other"},{"subitem_subject":"electro-magnetic transients program (EMTP)","subitem_subject_scheme":"Other"},{"subitem_subject":"fuzzy logic controller (FLC)","subitem_subject_scheme":"Other"},{"subitem_subject":"proportional-integral (PI) controller","subitem_subject_scheme":"Other"},{"subitem_subject":"superconductive magnetic energy storage (SMES)","subitem_subject_scheme":"Other"},{"subitem_subject":"transient stability augmentation","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A Fuzzy Logic-Controlled Superconducting Magnetic Energy Storage (SMES) for Transient Stability Augmentation","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A Fuzzy Logic-Controlled Superconducting Magnetic Energy Storage (SMES) for Transient Stability Augmentation","subitem_title_language":"en"}]},"item_type_id":"3","owner":"1","path":["87"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-01-26"},"publish_date":"2008-01-26","publish_status":"0","recid":"7238","relation_version_is_last":true,"title":["A Fuzzy Logic-Controlled Superconducting Magnetic Energy Storage (SMES) for Transient Stability Augmentation"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-13T02:24:55.161498+00:00"}