{"created":"2021-03-01T05:59:41.301440+00:00","id":7237,"links":{},"metadata":{"_buckets":{"deposit":"c79d3cf2-4c67-4b2a-8eb9-3420bc9cace0"},"_deposit":{"id":"7237","owners":[],"pid":{"revision_id":0,"type":"depid","value":"7237"},"status":"published"},"_oai":{"id":"oai:kitami-it.repo.nii.ac.jp:00007237","sets":["1:87"]},"author_link":["37107","37108","37109"],"item_1646810750418":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_3_biblio_info_186":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"1330","bibliographicPageStart":"1321","bibliographicVolumeNumber":"21","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Power Systems"}]}]},"item_3_description_184":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper analyzes the effect of the coordination of optimal reclosing and fuzzy logic-controlled braking resistor on the transient stability of a multimachine power system in case of an unsuccessful reclosing of circuit breakers. The transient stability performance of the coordinated operation of optimal reclosing and fuzzy controlled braking resistor is compared to that of the coordinated operation of conventional auto-reclosing and fuzzy controlled braking resistor. The effectiveness of the proposed method is confirmed by simulations in case of a nine-bus power system model as well as a ten-machine system. Simulation results of both balanced and unbalanced faults at different points in the power systems show that the coordinated operation of optimal reclosing and fuzzy controlled braking resistor is able to stabilize the systems well in case of an unsuccessful reclosing. Moreover, the transient stability performance of the coordinated operation of optimal reclosing and fuzzy controlled braking resistor is better than that of the coordinated operation of conventional auto-reclosing and fuzzy controlled braking resistor.","subitem_description_type":"Abstract"}]},"item_3_description_194":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_3_publisher_212":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electrical and Electronics Engineers"}]},"item_3_relation_191":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1109/TPWRS.2006.876670","subitem_relation_type_select":"DOI"}}]},"item_3_select_195":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ali, Mohd.Hasan","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Murata, Toshiaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tamura, Junji","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-22"}],"displaytype":"detail","filename":"ieee21_1321-1330.pdf","filesize":[{"value":"9.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ieee21_1321-1330.pdf","url":"https://kitami-it.repo.nii.ac.jp/record/7237/files/ieee21_1321-1330.pdf"},"version_id":"85fdbc8b-fc04-4bc6-a4f2-316b92409e96"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"balanced faults","subitem_subject_scheme":"Other"},{"subitem_subject":"braking resistor (BR)","subitem_subject_scheme":"Other"},{"subitem_subject":"fuzzy controller","subitem_subject_scheme":"Other"},{"subitem_subject":"global positioning system (GPS)","subitem_subject_scheme":"Other"},{"subitem_subject":"optimal reclosing","subitem_subject_scheme":"Other"},{"subitem_subject":"power system transient stability","subitem_subject_scheme":"Other"},{"subitem_subject":"unbalanced faults","subitem_subject_scheme":"Other"},{"subitem_subject":"unsuccessful reclosing","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Effect of coordination of optimal reclosing and fuzzy controlled braking resistor on transient stability during unsuccessful reclosing","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Effect of coordination of optimal reclosing and fuzzy controlled braking resistor on transient stability during unsuccessful reclosing","subitem_title_language":"en"}]},"item_type_id":"3","owner":"1","path":["87"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-01-26"},"publish_date":"2008-01-26","publish_status":"0","recid":"7237","relation_version_is_last":true,"title":["Effect of coordination of optimal reclosing and fuzzy controlled braking resistor on transient stability during unsuccessful reclosing"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-13T02:23:11.841786+00:00"}