@article{oai:kitami-it.repo.nii.ac.jp:00006883, author = {AKPAN, Itoro Etim and Sasaki, Masafumi and ENDOH, Noboru}, issue = {3}, journal = {JSME International Journal Series B}, month = {Aug}, note = {A simplified double grade meteorological data model for the simulation of the annual performance of a domestic-size renewable energy system is proposed. With the model, only two representative days (clearest and cloudiest) during each season of the year are necessary to estimate annual energy balances, carbon emissions and the running costs. The model was chosen in preference to other simplified models based on the error distributions from the results of the continuous simulations in a test period. Detailed numerical simulation studies show that the carbon emissions from the renewable energy system are about 16% of a comparable conventional system. The thermal energy produced by a solar collector during the winter season, however, is insufficient to meet all the loads so that frequent heat pump operations and the auxiliary boiler are necessary in cold climate regions., application/pdf}, pages = {839--846}, title = {Simplifications of Simulation on Energy Balances and Estimations of a Hybrid Renewable Energy System for Use in Cold Climate Regions}, volume = {49}, year = {2006} }