{"created":"2021-03-01T05:59:16.712358+00:00","id":6836,"links":{},"metadata":{"_buckets":{"deposit":"ffd29e0a-3764-4184-be8c-419553345e98"},"_deposit":{"id":"6836","owners":[],"pid":{"revision_id":0,"type":"depid","value":"6836"},"status":"published"},"_oai":{"id":"oai:kitami-it.repo.nii.ac.jp:00006836","sets":["1:87"]},"author_link":["34543","44852","34539","34540","34541","34542"],"item_1646810750418":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_3_biblio_info_186":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"364","bibliographicPageStart":"359","bibliographicVolumeNumber":"1","bibliographic_titles":[{"bibliographic_title":"Transmission and Distribution Conference and Exhibition 2002: Asia Pacific. IEEE/PES"}]}]},"item_3_description_184":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents the results of analyses of the effectiveness of a Superconducting Fault Current Limiter (SFCL) on improving power system transient stability and limiting the fault current in a two-machine-infinite bus system. In this study, the system model with two SFCLs installed at each generator terminal was used taking 3LG (three lines to ground) fault at 12 fault points into account. These analyses were performed using EMTP/ATP. It is concluded that the use of SFCL with shunt resistance value of about 1.0 pu is effective for all fault points for the improvement of power system transient stability and the limiting of fault current.","subitem_description_type":"Abstract"}]},"item_3_description_194":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_3_full_name_183":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"34543","nameIdentifierScheme":"WEKO"}],"names":[{"name":"村田, 年昭","nameLang":"ja"}]},{"nameIdentifiers":[{"nameIdentifier":"44852","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"40171897","nameIdentifierScheme":"KAKEN","nameIdentifierURI":"https://nrid.nii.ac.jp/ja/nrid/1000040171897 "}],"names":[{"name":"田村, 淳二","nameLang":"ja"}]}]},"item_3_publisher_212":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electrical and Electronics Engineers"}]},"item_3_relation_191":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1109/TDC.2002.1178367","subitem_relation_type_select":"DOI"}}]},"item_3_rights_192":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"IEEE, Yagami, M., Shibata, S., Murata, T., Tamura, J., Transmission and Distribution Conference and Exhibition 2002: Asia Pacific. IEEE/PES, 1, 2002, 359-364. c2002 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE."}]},"item_3_select_195":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yagami, Masaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shibata, Shinsuke","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Murata, Toshiaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tamura, Junji","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-22"}],"displaytype":"detail","filename":"4504.pdf","filesize":[{"value":"472.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"4504.pdf","url":"https://kitami-it.repo.nii.ac.jp/record/6836/files/4504.pdf"},"version_id":"c868618d-68e3-451e-8aea-32db71f71675"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Improvement of Power System Transient Stability by Superconducting Fault Current Limiter","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Improvement of Power System Transient Stability by Superconducting Fault Current Limiter","subitem_title_language":"en"}]},"item_type_id":"3","owner":"1","path":["87"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-04-19"},"publish_date":"2007-04-19","publish_status":"0","recid":"6836","relation_version_is_last":true,"title":["Improvement of Power System Transient Stability by Superconducting Fault Current Limiter"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-13T02:24:52.785377+00:00"}