{"created":"2021-03-01T05:59:00.393920+00:00","id":6570,"links":{},"metadata":{"_buckets":{"deposit":"06adb6e8-3e8a-4120-bb73-3537cf474dd8"},"_deposit":{"created_by":188,"id":"6570","owners":[188],"pid":{"revision_id":0,"type":"depid","value":"6570"},"status":"published"},"_oai":{"id":"oai:kitami-it.repo.nii.ac.jp:00006570","sets":["7:15:37"]},"author_link":["33120","33121","33122","33123","33124","44852","33116","33117","33118","33119"],"item_2_alternative_title_18":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Analysis of the Unsymmetrical Sudden Short-Circuit of an AC Excited Synchronous Machine (Part 2)-One Line-to-Ground Fault-","subitem_alternative_title_language":"en"}]},"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1985-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"88","bibliographicPageStart":"79","bibliographicVolumeNumber":"16","bibliographic_titles":[{"bibliographic_title":"北見工業大学研究報告","bibliographic_titleLang":"ja"}]}]},"item_2_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The line-to-line fault of AESM was analyzed in the preceding paper. In this paper, analysis of the one line-to-ground fault is presented. As we intend to use the AESM as a driving motor-generator in the flywheel energy storage system, it is necessary to analyze the above single-phase asymmetrical faults (line-to-line and one line-to-ground). First, after brief discussion of the line-to-line fault, the basic differential equations for the one line-to-ground fault of a secondary winding are derived. Next the solutions for that fault are derived from the solutions for the line-to-line fault of a secondary winding by transformation of circuit constants and variables. Furthermore the fault of a primary winding is also analyzed and the solutions are derived from those for the line-to-line fault by the same transformation. Finally the short-circuit torques for the line-to-line fault and one line-to-ground fault are discussed","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_2_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"33120","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Junji, TAMURA","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"33121","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Toshiaki, MURATA","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"33122","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Ikuo, TAKEDA","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"33123","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Jun, HASEGAWA","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"33124","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Hajime, FUJIWARA","nameLang":"en"}]}]},"item_2_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"北見工業大学","subitem_publisher_language":"ja"}]},"item_2_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":["publisher"],"subitem_select_language":"en"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田村, 淳二","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"44852","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"1000040171897","nameIdentifierScheme":"NRID","nameIdentifierURI":"https://nrid.nii.ac.jp/nrid/1000040171897"}]},{"creatorNames":[{"creatorName":"村田, 年昭","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"33116","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"武田, 郁夫","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"33117","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川, 淳","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"33118","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤原, 一","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"33119","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2007-04-09"}],"displaytype":"detail","filename":"16-2-2.pdf","filesize":[{"value":"3.6 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"16-2-2.pdf","url":"https://kitami-it.repo.nii.ac.jp/record/6570/files/16-2-2.pdf"},"version_id":"9c9972e6-a4e1-4843-ae42-1dfc8ae9fb56"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"交流励磁型同期機の不平衡突発短絡に関する解析 (第2報) ー線地絡故障ー","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"交流励磁型同期機の不平衡突発短絡に関する解析 (第2報) ー線地絡故障ー","subitem_title_language":"ja"}]},"item_type_id":"2","owner":"188","path":["37"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2007-04-09"},"publish_date":"2007-04-09","publish_status":"0","recid":"6570","relation_version_is_last":true,"title":["交流励磁型同期機の不平衡突発短絡に関する解析 (第2報) ー線地絡故障ー"],"weko_creator_id":"188","weko_shared_id":-1},"updated":"2025-01-30T05:27:15.503463+00:00"}