@article{oai:kitami-it.repo.nii.ac.jp:00006498, author = {中村, 陽一 and 山城, 迪}, issue = {1}, journal = {北見工業大学研究報告}, month = {Jan}, note = {application/pdf, In this paper, our series of reports on the question of “Startup and Shutdown Problem of Thermal Generating Units with Constrained Total Nitrogen Oxides Emissions” is expanded to cover the case of including a pumping-up power station, and we describe the calculating method used for this problem. We test our method by a model system, and consider its appropriateness. It is shown that when we simply apply the convenient rule of “generating operation at peak load, and pumping operation at base load”, we fail to find the optimum operation. We show that the reason for this failure is the change of unit commitment and the value of the emission constraint. Using curves of the total cost versus total emission constraint for both the case of including a pumping-up power station and that of not including it, we show that the operation of a pumping-up power station is also useful under the total nitrogen oxides emission constraint for the thermal power plants.}, pages = {49--57}, title = {NO_Xの累積排出量が制約された場合の火力発電機群起動停止問題 (第5報)* -揚水式発電所を系統に含む場合-}, volume = {12}, year = {1981} }