<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-05T11:26:19Z</responseDate>
  <request verb="GetRecord" metadataPrefix="jpcoar_2.0" identifier="oai:kitami-it.repo.nii.ac.jp:00006345">https://kitami-it.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:kitami-it.repo.nii.ac.jp:00006345</identifier>
        <datestamp>2025-01-30T05:15:18Z</datestamp>
        <setSpec>7:15:27</setSpec>
      </header>
      <metadata>
        <jpcoar:jpcoar xmlns:datacite="https://schema.datacite.org/meta/kernel-4/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcndl="http://ndl.go.jp/dcndl/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:jpcoar="https://github.com/JPCOAR/schema/blob/master/2.0/" xmlns:oaire="http://namespace.openaire.eu/schema/oaire/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:rioxxterms="http://www.rioxx.net/schema/v2.0/rioxxterms/" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns="https://github.com/JPCOAR/schema/blob/master/2.0/" xsi:schemaLocation="https://github.com/JPCOAR/schema/blob/master/2.0/jpcoar_scm.xsd">
          <dc:title xml:lang="ja">フォールコーン法による液性塑性両限界の測定</dc:title>
          <dcterms:alternative xml:lang="en">Measurement of Liquid and Plastic Limits by Fall Cone Test</dcterms:alternative>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">鈴木, 輝之</jpcoar:creatorName>
          </jpcoar:creator>
          <datacite:description descriptionType="Other">application/pdf</datacite:description>
          <datacite:description xml:lang="en" descriptionType="Abstract">Consistency limits are often used as an index to show the properties of cohesive soils. In spite of its usefullness， the conventional method of measurement of consistency limits has many disadvantages such as the human effects，the difficulty of standardizing the measuring devices，etc. This investigatigation is an　attempt to eliminate these defects by using the fall cone test.　　In this paper，experimental results and subsequent discussions of the fan cone test to measure liquid and plastic limits are presented. Also in this study，it is found that liquid and plastic limits are both measurable with one series of fall cone tests using improved techniques.</datacite:description>
          <dc:publisher xml:lang="ja">北見工業大学</dc:publisher>
          <datacite:date dateType="Issued">1974-03</datacite:date>
          <dc:language>jpn</dc:language>
          <dc:type rdf:resource="http://purl.org/coar/resource_type/c_6501">departmental bulletin paper</dc:type>
          <jpcoar:identifier identifierType="URI">https://kitami-it.repo.nii.ac.jp/records/6345</jpcoar:identifier>
          <jpcoar:sourceTitle xml:lang="ja">北見工業大学研究報告</jpcoar:sourceTitle>
          <jpcoar:volume>5</jpcoar:volume>
          <jpcoar:issue>2</jpcoar:issue>
          <jpcoar:pageStart>188</jpcoar:pageStart>
          <jpcoar:pageEnd>194</jpcoar:pageEnd>
          <jpcoar:file>
            <jpcoar:URI label="5-2-4.pdf">https://kitami-it.repo.nii.ac.jp/record/6345/files/5-2-4.pdf</jpcoar:URI>
            <jpcoar:mimeType>application/pdf</jpcoar:mimeType>
            <jpcoar:extent>3.4 MB</jpcoar:extent>
            <datacite:date dateType="Available">2016-11-22</datacite:date>
          </jpcoar:file>
        </jpcoar:jpcoar>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
