下水処理施設におけるマイクロガスタービンコジェネレーションシステムの性能評価 : 年間平均気温の異なる地域での性能解析
Performance Evaluation of Micro Gas Turbine Cogeneration System at Sewage Treatment Plant : Performance Analysis under Various Regions with Different Annual Average Temperature
Performance Evaluation of Micro Gas Turbine Cogeneration System at Sewage Treatment Plant : Performance Analysis under Various Regions with Different Annual Average Temperature
BASRAWI, Firdaus
山田, 貴延
中西, 喜美雄
open access
c2010 日本機械学会
Energy Saving
Energy Storage
Biomass Energy
Cogeneration
Micro Gas Turbine
Methane Hydrate
This study shows an impact and a basic performance analysis of micro gas turbine (MGT) cogeneration system (CGS) in the sewage treatment facility under various temperature conditions. The results show that, in either temperature condition, by only using biogas produced from the facility as a fuel and methane hydrate storage method as solution for the unbalance of biogas produced, MGT-CGS is sufficiently capable to cover all the total heat demand of the facility. On the biogas utilization and economic point of views, MGT-CGS is effective in either temperature conditions but the effectiveness is decreasing when the ambient temperature condition is increasing. It is most effective in cold temperature condition with almost 100% of the biogas is utilized, whereas in high temperature condition due to low heat demand, comparing to the conventional system approximately only 42~79% of unutilized biogas is decreased. While adopting an actual data as a part of the calculation procedure, results of the impact and performance analysis are shown in the paper.
一般社団法人日本機械学会
2010-10
jpn
journal article
VoR
https://kitami-it.repo.nii.ac.jp/records/7588
日本機械学会論文集 B編
76
770
1661
1670
https://kitami-it.repo.nii.ac.jp/record/7588/files/No32.pdf
application/pdf
1.2 MB
2016-11-22