{"_buckets": {"deposit": "fec06232-a016-4eaa-b29b-9a16e3348628"}, "_deposit": {"id": "8417", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "8417"}, "status": "published"}, "_oai": {"id": "oai:kitami-it.repo.nii.ac.jp:00008417", "sets": ["86"]}, "author_link": ["44295", "44296", "44297", "44298", "44852", "44292", "44293", "44294"], "item_1646810750418": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_3_alternative_title_198": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "A Consideration on the Voltage Stability of Wind Generators"}]}, "item_3_biblio_info_186": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "1130", "bibliographicPageStart": "1129", "bibliographicVolumeNumber": "122", "bibliographic_titles": [{"bibliographic_title": "電気学会論文誌B"}]}]}, "item_3_description_184": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Recently the wind power generation has attracted special interest and many wind power stations are being in service in the world. In the wind power stations, induction machines are mostly used as a generator. Since induction machines can become unstable during a fault in power system, like a step-out of synchronous machines, it is important to analyze the stability of power system including wind generators. This paper presents a consideration on the stability of induction generators from a point of view of voltage stability.", "subitem_description_type": "Abstract"}]}, "item_3_full_name_183": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "44295", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tamura, Junji", "nameLang": "en"}]}, {"nameIdentifiers": [{"nameIdentifier": "44296", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yonaga, Shigeru", "nameLang": "en"}]}, {"nameIdentifiers": [{"nameIdentifier": "44297", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Matsumura, Yoshiharu", "nameLang": "en"}]}, {"nameIdentifiers": [{"nameIdentifier": "44298", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kubo, Hiroshi", "nameLang": "en"}]}]}, "item_3_publisher_212": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "一般社団法人 電気学会"}]}, "item_3_rights_192": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c 2002 電気学会"}]}, "item_3_select_195": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_3_subject_196": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "540", "subitem_subject_scheme": "NDC"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "田村, 淳二", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "44852", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40171897", "nameIdentifierScheme": "KAKEN", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000040171897 "}]}, {"creatorNames": [{"creatorName": "世永, 茂", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "44292", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松村, 喜治", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "44293", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "久保, 宏", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "44294", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-01-12"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "2002_風力発電機の電圧安定性に関する考察 (研究開発レター).pdf", "filesize": [{"value": "202.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 202800.0, "url": {"label": "2002_風力発電機の電圧安定性に関する考察 (研究開発レター).pdf", "url": "https://kitami-it.repo.nii.ac.jp/record/8417/files/2002_風力発電機の電圧安定性に関する考察 (研究開発レター).pdf"}, "version_id": "0d6477c4-3665-4513-a251-a66b2e994564"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "風力発電", "subitem_subject_scheme": "Other"}, {"subitem_subject": "誘導発電機", "subitem_subject_scheme": "Other"}, {"subitem_subject": "電力系統", "subitem_subject_scheme": "Other"}, {"subitem_subject": "電圧安定性", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "風力発電機の電圧安定性に関する考察", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "風力発電機の電圧安定性に関する考察", "subitem_title_language": "ja"}, {"subitem_title": "A Consideration on the Voltage Stability of Wind Generators", "subitem_title_language": "en"}]}, "item_type_id": "3", "owner": "1", "path": ["86"], "permalink_uri": "https://kitami-it.repo.nii.ac.jp/records/8417", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2016-08-19"}, "publish_date": "2016-08-19", "publish_status": "0", "recid": "8417", "relation": {}, "relation_version_is_last": true, "title": ["風力発電機の電圧安定性に関する考察"], "weko_shared_id": -1}
風力発電機の電圧安定性に関する考察
https://kitami-it.repo.nii.ac.jp/records/8417
https://kitami-it.repo.nii.ac.jp/records/84179eb646b9-dd93-4026-8729-f55dce4d4406
名前 / ファイル | ライセンス | アクション |
---|---|---|
2002_風力発電機の電圧安定性に関する考察 (研究開発レター).pdf (202.8 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-08-19 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 風力発電機の電圧安定性に関する考察 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | A Consideration on the Voltage Stability of Wind Generators | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 風力発電 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 誘導発電機 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 電力系統 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 電圧安定性 | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
その他のタイトル | ||||||
その他のタイトル | A Consideration on the Voltage Stability of Wind Generators | |||||
著者 |
田村, 淳二
× 田村, 淳二× 世永, 茂× 松村, 喜治× 久保, 宏 |
|||||
著者別名 | ||||||
姓名 | Tamura, Junji | |||||
言語 | en | |||||
著者別名 | ||||||
姓名 | Yonaga, Shigeru | |||||
言語 | en | |||||
著者別名 | ||||||
姓名 | Matsumura, Yoshiharu | |||||
言語 | en | |||||
著者別名 | ||||||
姓名 | Kubo, Hiroshi | |||||
言語 | en | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Recently the wind power generation has attracted special interest and many wind power stations are being in service in the world. In the wind power stations, induction machines are mostly used as a generator. Since induction machines can become unstable during a fault in power system, like a step-out of synchronous machines, it is important to analyze the stability of power system including wind generators. This paper presents a consideration on the stability of induction generators from a point of view of voltage stability. | |||||
書誌情報 |
電気学会論文誌B 巻 122, 号 10, p. 1129-1130, 発行日 2002-10 |
|||||
権利 | ||||||
権利情報 | c 2002 電気学会 | |||||
出版者 | ||||||
出版者 | 一般社団法人 電気学会 | |||||
著者版フラグ | ||||||
値 | publisher | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |