{"_buckets": {"deposit": "b6a5823f-dcaf-493f-8cd3-2f309031bdd3"}, "_deposit": {"id": "8425", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "8425"}, "status": "published"}, "_oai": {"id": "oai:kitami-it.repo.nii.ac.jp:00008425", "sets": ["87"]}, "author_link": ["44356", "44851", "44852", "44352", "44353", "44354", "44355"], "item_1646810750418": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_3_biblio_info_186": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "1110", "bibliographicPageStart": "1101", "bibliographicVolumeNumber": "124", "bibliographic_titles": [{"bibliographic_title": "IEEJ Transactions on Power and Energy"}]}]}, "item_3_description_184": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This paper investigates the function of DASM (Doubly-fed ASynchronous Machine) with emphasis placed on its ability to the stabilization of the power system including wind generators. P (active power) and Q (reactive power) compensation from DASM can be regulated independently through secondary-excitation controlling. Simulation results by PSCAD show that DASM can restore the wind-generator system to a normal operating condition rapidly even following severe transmission-line failures. Comparison studies have also been performed between wind turbine pitch control and proposed method.", "subitem_description_type": "Abstract"}]}, "item_3_full_name_183": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "44356", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tamura, Junji", "nameLang": "en"}]}, {"nameIdentifiers": [{"nameIdentifier": "44851", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60301975", "nameIdentifierScheme": "KAKEN", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000060301975 "}], "names": [{"name": "高橋, 理音", "nameLang": "ja"}]}, {"nameIdentifiers": [{"nameIdentifier": "44852", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40171897", "nameIdentifierScheme": "KAKEN", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000040171897 "}], "names": [{"name": "田村, 淳二", "nameLang": "ja"}]}]}, "item_3_publisher_212": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "The Institute of Electrical Engineers of Japan"}]}, "item_3_relation_191": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://doi.org/10.1541/ieejpes.124.1101", "subitem_relation_type_select": "DOI"}}]}, "item_3_rights_192": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "c 2004 by the Institute of Electrical Engineers of Japan"}]}, "item_3_select_195": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_3_subject_196": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "540", "subitem_subject_scheme": "NDC"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Wu, Li", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "44352", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahashi, Rion", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "44353", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakagawa, Masaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "44354", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murata, Toshiaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "44355", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-01-12"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "2004_A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine.pdf", "filesize": [{"value": "221.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 221100.0, "url": {"label": "2004_A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine.pdf", "url": "https://kitami-it.repo.nii.ac.jp/record/8425/files/2004_A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine.pdf"}, "version_id": "115d6489-0f74-4e50-80d4-8999f96520dc"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "DASM (doubly-fed asynchronous machine)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "wind generator", "subitem_subject_scheme": "Other"}, {"subitem_subject": "wind turbine pitch control", "subitem_subject_scheme": "Other"}, {"subitem_subject": "PSCAD/EMTDC", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine", "subitem_title_language": "en"}]}, "item_type_id": "3", "owner": "1", "path": ["87"], "permalink_uri": "https://kitami-it.repo.nii.ac.jp/records/8425", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2016-08-19"}, "publish_date": "2016-08-19", "publish_status": "0", "recid": "8425", "relation": {}, "relation_version_is_last": true, "title": ["A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine"], "weko_shared_id": -1}
A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine
https://kitami-it.repo.nii.ac.jp/records/8425
https://kitami-it.repo.nii.ac.jp/records/84252981890e-5c29-484d-be09-f128fa96bd01
名前 / ファイル | ライセンス | アクション |
---|---|---|
2004_A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine.pdf (221.1 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-08-19 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | A Basic Study of Wind Generator Stabilization with Doubly-Fed Asynchronous Machine | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | DASM (doubly-fed asynchronous machine) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | wind generator | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | wind turbine pitch control | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | PSCAD/EMTDC | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
著者 |
Wu, Li
× Wu, Li× Takahashi, Rion× Nakagawa, Masaki× Murata, Toshiaki |
|||||
著者別名 | ||||||
姓名 | Tamura, Junji | |||||
言語 | en | |||||
著者別名 | ||||||
姓名 | 高橋, 理音 | |||||
言語 | ja | |||||
著者別名 | ||||||
姓名 | 田村, 淳二 | |||||
言語 | ja | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This paper investigates the function of DASM (Doubly-fed ASynchronous Machine) with emphasis placed on its ability to the stabilization of the power system including wind generators. P (active power) and Q (reactive power) compensation from DASM can be regulated independently through secondary-excitation controlling. Simulation results by PSCAD show that DASM can restore the wind-generator system to a normal operating condition rapidly even following severe transmission-line failures. Comparison studies have also been performed between wind turbine pitch control and proposed method. | |||||
書誌情報 |
IEEJ Transactions on Power and Energy 巻 124, 号 9, p. 1101-1110, 発行日 2004-09 |
|||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://doi.org/10.1541/ieejpes.124.1101 | |||||